Detect a fire detectors are the heart of many fire protection systems.
Thermal detectors fire protection.
These highly reliable devices have been a standard for over 65 years.
Throughout this time i have always found protectowire products to be best in class.
From gas stations to paint spray booths from range hoods to large power generation systems from engine compartments to schools factories and offices the d a f detector is on guard.
The thermal mass and conductivity of the element regulate the rate flow of heat into the element.
I have been a protectowire distributor for 25 years.
Fds pyroview pyrosoft.
Linear heat detectors by protectowire can best be described as a continuous run of spot heat detectors within a versatile cable.
A heat detector is a fire alarm device designed to respond when the convected thermal energy of a fire increases the temperature of a heat sensitive element.
Out of kenilworth new jersey installed a fiber optic linear heat detection system for railroad platform protection in north america s busiest train station five years ago.
Gasoline fume detectors marine propane detection our thermal imaging fire detection system is a reliable system for surveillance and recognition of spontaneous fires inside bunkers coal conveyers rubbish dumps paper and cardboard recycling plants and the like.
Designed for use in a wide variety of indoor and outdoor applications lhd fire alarm cables are particularly suited for areas where installation or maintenance access is in a physically demanding or hazardous.
All heat detectors have this thermal lag heat detectors have two main classifications of operation rate of rise and fixed temperature.
Thousands of these detectors are in use controlling the release of clean agents co2 water or dry chemicals.
The interconnect system must not exceed the nfpa national fire protection association limit of 18 initiating devices smoke heat co etc.
Our fire detection system is a reliable system for surveillance and recognition of spontaneous fires inside bunkers or free air dumps of waste or combustible materials like paper waste or charcoal among many others.
The kidde firex hd135f is a 120 volt ac the kidde firex hd135f is a 120 volt ac wire in heat alarm that responds to temperature rather than smoke.
Bs 5839 states that detectors should be sited no less than 0 5m from a wall.
My company united fire protection corp.
The alarm will sound if temperatures rise above 135 f.
The world standard in mechanical heat detectors a detect a fire detector is the heart of many fire protection systems and has been for over 65 years as the first rate compensated detector on the market.
With heat detectors this figure is 7 5m x 7 5m giving an area of coverage of 56m per device which is rounded down to 50m.